Scitus

  • Accurate and jam-free dispensing
  • Fully Autoclavable at 121° C, 15psi. for 10-15 mins
  • High chemical compatibility with SpringlessValveTM and PTFE piston
  • Optimized user experience with EasyKnob™ and FlexiNozzle™
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit Scitus is a Bottle Top Dispenser that works on Springless ValveTM Technology. Designed with ergonomics and intuitive handling in mind, it offers excellent chemical compatibility and enables the achievement of precision in practical laboratory environments. Scitus also features two product innovations: EasyKnob™ and FlexiNozzle™ that enhance its usability.

What’s in the box?

  1. Dispensing unit
  2. Calibration certificate
  3. Calibration Tool
  4. Bottle Adaptors for all standard reagent bottle neck sizes (28mm – 45mm)
  5. Instruction Manual

Applications

Microlit Scitus, a bottle dispenser, is more than just a scientific instrument. It has a wide application in standard laboratory environments such as pharmaceuticals, academics, research institutes, healthcare institutions, and the food & beverage industry to dispenser solvents, corrosive acids, and other reagents. Scitus may also be used in emerging industries as an e-liquid bottle dispenser, essential oils bottle dispenser, Hemp Oil dispenser, and Vape liquid dispenser, in addition to being used as an acids bottle dispenser and solvents bottle dispenser in the laboratory.

With increasing industrial demand, the popularity of Microlit bottle top dispensers is expected to go as more industries discover the top-notch quality, high functionality, and assured improvement in efficiency that the bottle dispenser offers.

Features
Change Volume with EasyKnob™

Change Volume with EasyKnob™

EasyKnob™ is a specially designed volume adjustment knob that allows 180° rotation for easy and effortless volume setting.

Move Effortlessly with a PTFE Piston

Move Effortlessly with a PTFE Piston

A PTFE Piston with an ETP O-Ring facilitates smooth and effortless movement and ensures high chemical compatibility.

Operate Jam-free with Springless Valve™

Operate Jam-free with Springless Valve™

MICROLIT SCITUS comes with an award-winning technology, Springless Valve™, that facilitates smooth and jam-free functioning.

Dispense Easily with FlexiNozzle™

Dispense Easily with FlexiNozzle™

FlexiNozzle™ is an adjustable delivery nozzle. It offers a high degree of flexibility, facilitating easy dispensing in demanding laboratory conditions.

Work Flexibly with a 360° Adapter

Work Flexibly with a 360° Adapter

A specially designed Adapter allows 360° rotation, facilitating complete work flexibility.

Model No. Description Vol. Range Increment Accuaracy CV
+% +ml +% +ml
SCI-2.5 Scitus Bottle Top Dispenser 0.25-2.5ml 0.25-2.5ml 0.05ml 0.5 0.0125 0.2 0.005
SCI-5 Scitus Bottle Top Dispenser 0.5-5ml 0.05ml 0.1ml 0.5 0.025 0.2 0.01
SCI-10 Scitus Bottle Top Dispenser 1-10ml 1-10ml 0.2ml 0.5 0.05 0.1 0.01
SCI-30 Scitus Bottle Top Dispenser 2.5-30ml 2.5-30ml 0.5ml 0.5 0.15 0.1 0.03
SCI-60 Scitus Bottle Top Dispenser 5-60ml 5-60ml 1.0ml 0.5 0.3 0.1 0.06
SCI-100 Scitus Bottle Top Dispenser 10-100ml 10-100ml 2.0ml 0.5 0.5 0.1 0.1

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance
with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-5.

What our Customers are saying

Purging or priming is performed to remove the air bubbles from the barrel. For priming, gently pull the piston up and then push down rapidly till the piston hits the base. Repeat this procedure for at least five times. If the problem still persists, please check the telescopic or inlet tube fitment.
Microlit dispensers are compatible with a wide range of reagents/chemicals as the materials of the wetted components of the dispenser (PTFE, Borosilicate glass, FEP, PP) do not react with the most commonly used reagents. For specific reagent compatibility please refer to our Chemical Compatibility Chart
Yes, the dispensers are fully autoclavable at 121 C for 15-20 min at 15 psi. However, do not put the dispenser in the autoclave without disassembly. Disassemble the piston and shaft from the dispenser before autoclaving. The volume-adjustment knob must be kept in an unlocked position. Lastly, re-calibration is necessary after autoclaving. Please refer to the instruction manual for the correct detailed autoclaving procedure.
Set the ml dispenser at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the dispenser is calibrated. If not, please follow the recalibration procedure in the instruction manual.
We recommend rinsing the dispenser with de-ionized or distilled water before and after the use. For detailed maintenance and cleaning of the dispenser, please refer to the product instruction manual.
The dispenser comes with a 5 set of adaptors of the size between 28, 32, 38,40, and 45mm that will allow the dispenser to be mounted on any standard reagent glass bottle.
The minimum length of the telescopic inlet tube of the bottle top dispenser is 170mm and is extendable up to 320 mm.
Yes, to work against the stronger acids, these acids bottle top dispensers are compatible as the wetted components of the dispenser (PTFE, PFA, Borosilicate glass, Zirconia, and FEP) are inert and do not react with them. However, it is strongly advised not to leave the instrument mounted over strong acids as it may cause discoloration or softening of the external material but it will NOT affect its functionality. Please refer to our Chemical Compatibility Chart
Yes, the dispenser can be used as an essential oils dispenser. However, we recommend using the fluids with a maximum viscosity of 500cP.
The dispenser may not be able to aspirate the liquid if the valve ball is stuck. It might happen due to the negative air pressure while air transportation. However, the following quick troubleshoot can easily be performed:
  • Check whether the Inlet tube is fitted firmly. If not, cut off the tube approx. 1cm from above and refix the tube again.
  • Check whether the ball in the valve system is stuck. Rinse the dispenser with distilled water so as to remove the reagent deposit inside the valve mechanism or Insert a thin wire at the inlet stub and push the ball with very little force to release the stuck valve ball.
Oil Bottle Dispenser

Beatus

with Re-circulation Valve
  • Accurate and jam-free dispensing
  • Re-circulation valve technology to prime instrument without loss of reagent
  • Fully Autoclavable at 121° C, 15psi. for 10-15 mins
  • High chemical compatibility with SpringlessValveTM and PTFE piston
  • Optimized user experience with EasyKnob™ and FlexiNozzle™
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit Beatus is a Bottle Top Dispenser that works on Recirculation Valve and Springless ValveTM Technology. Designed with ergonomics and intuitive handling in mind, it offers excellent chemical compatibility and enables the achievement of precision in practical laboratory environments. Beatus also features two product innovations: EasyKnob™ and FlexiNozzle™ that enhance its usability.

What’s in the box?

  1. Dispensing unit
  2. Calibration certificate
  3. Calibration Tool
  4. Bottle Adaptors for all standard reagent bottle neck sizes (28mm – 45mm)
  5. Instruction Manual

Applications

Microlit Beatus, a bottle dispenser, is more than just a scientific instrument. It has a wide application in standard laboratory environments such as pharmaceuticals, academics, research institutes, healthcare institutions, and the food & beverage industry to dispenser solvents, corrosive acids, and other reagents. Scitus may also be used in emerging industries as an e-liquid bottle dispenser, essential oils bottle dispenser, Hemp Oil dispenser, and Vape liquid dispenser, in addition to being used as an acids bottle dispenser and solvents bottle dispenser in the laboratory.

With increasing industrial demand, the popularity of Microlit bottle top dispensers is expected to go as more industries discover the top-notch quality, high functionality, and assured improvement in efficiency that the bottle dispenser offers.

Features
Change Volume with EasyKnob™

Change Volume with EasyKnob™

EasyKnob™ is a specially designed volume adjustment knob that allows 180° rotation for easy and effortless volume setting.

Move Effortlessly with a PTFE Piston

Move Effortlessly with a PTFE Piston

A PTFE Piston with an ETP O-Ring facilitates smooth and effortless movement and ensures high chemical compatibility.

Re-direct Liquids with Recirculation Valve

Re-direct Liquids with Recirculation Valve

Recirculation Valve prevents the loss of reagents during purging by re-directing them into the mounted bottle and facilitates bubble free dispensing.

Operate Jam-free with Springless Valve™

Operate Jam-free with Springless Valve™

MICROLIT BEATUS comes with an award-winning technology, Springless Valve™, that facilitates smooth and jam-free functioning.

Dispense Easily with FlexiNozzle™

Dispense Easily with FlexiNozzle™

FlexiNozzle™ is an adjustable delivery nozzle. It offers a high degree of flexibility, facilitating easy dispensing in demanding laboratory conditions.

Work Flexibly with a 360° Adapter

Work Flexibly with a 360° Adapter

A specially designed Adapter allows 360° rotation, facilitating complete work flexibility.

Model No. Description Vol. Range Increment Accuracy CV
+% +ml +% +ml
BEAT-2.5 Beatus Bottle Top Dispenser 0.25-2.5ml 0.25-2.5ml 0.05ml 0.5 0.0125 0.2 0.005
BEAT-5 Beatus Bottle Top Dispenser 0.5-5ml 0.05ml 0.1ml 0.5 0.025 0.2 0.01
BEAT-10 Beatus Bottle Top Dispenser 1-10ml 1-10ml 0.2ml 0.5 0.05 0.1 0.01
BEAT-30 Beatus Bottle Top Dispenser 2.5-30ml 2.5-30ml 0.5ml 0.5 0.15 0.1 0.03
BEAT-60 Beatus Bottle Top Dispenser 5-60ml 5-60ml 1.0ml 0.5 0.3 0.1 0.06
BEAT-100 Beatus Bottle Top Dispenser 10-100ml 10-100ml 2.0ml 0.5 0.5 0.1 0.1

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance
with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-5.

What our Customers are saying

Purging or priming is performed to remove the air bubbles from the barrel. For priming, gently pull the piston up and then push down rapidly till the piston hits the base. Repeat this procedure for at least five times. If the problem still persists, please check the telescopic or inlet tube fitment.
Microlit bottle dispensers are compatible with a wide range of reagents/chemicals as the materials of the wetted components of the dispenser (PTFE, Borosilicate glass, FEP, PP) do not react with the most commonly used reagents. For specific reagent compatibility please refer to our Chemical Compatibility Chart
Yes, the dispensers are fully autoclavable at 121 C for 15-20 min at 15 psi. However, do not put the dispenser in the autoclave without disassembly. Disassemble the piston and shaft from the dispenser before autoclaving. The volume-adjustment knob must be kept in an unlocked position. Lastly, re-calibration is necessary after autoclaving. Please refer to the instruction manual for the correct detailed autoclaving procedure.
Set the ml dispenser at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the dispenser is calibrated. If not, please follow the recalibration procedure in the instruction manual.
We recommend rinsing the dispenser with de-ionized or distilled water before and after the use. For detailed maintenance and cleaning of the dispenser, please refer to the product instruction manual.
We adjust the piston so that it is smooth and does not require excessive force to dispense. This may result in auto-dispensing after the liquid is aspirated. However, this is not a problem and will not affect the accuracy of the instrument. It is recommended to immediately dispense the liquid after aspiration.
We recommend maintaining the temperature of the instrument and the reagent between +15 C to +40 C.
The dispenser comes with a 5 set of adaptors of the size between 28, 32, 38,40, and 45mm that will allow the dispenser to be mounted on any standard reagent glass bottle.
The minimum length of the telescopic inlet tube of the bottle top dispenser is 170mm and is extendable up to 320 mm.
Yes, to work against the stronger acids, these acids bottle top dispensers are compatible as the wetted components of the dispenser (PTFE, PFA, Borosilicate glass, Zirconia, and FEP) are inert and do not react with them. However, it is strongly advised not to leave the instrument mounted over strong acids as it may cause discoloration or softening of the external material but it will NOT affect its functionality. Please refer to our Chemical Compatibility Chart
Bottle Dispenser

Ultimus

with Dual Inlet Technology
  • Accurate and jam-free dispensing
  • Rinsing, Dilution, Re-filling and Purging modes with Dual InletTM
  • Recirculation valve technology to prime instrument without loss of reagent
  • Fully Autoclavable at 121° C, 15psi. for 10-15 mins
  • High chemical compatibility with SpringlessValveTM and PTFE piston
  • Optimized user experience with EasyKnob™ and FlexiNozzle™
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit Ultimus is a Bottle Top Dispenser that works on Dual InletTM Technology, Recirculation Valve Technology and Springless ValveTM Technology. The Dual Inlet Technology, patented in the US and EU, enables 4 liquid handling modes – rinsing, dilution, refilling & purging without dismounting the dispenser.

Standard Dispensing: Knob A – Open, Knob B – Closed

In this mode, the dispenser dispenses the liquid normally into the receiver from the bottle it is mounted on.

Purging: Knob A – Closed, Knob B – Closed

In this mode, the liquid is recirculated into the same bottle on which the dispenser is mounted. This process removes the air from the dispenser, without wasting any reagent.

Dilution/Rinsing/Second Liquid Dispensing: Knob A – Open, Knob B – Open

In this mode,the liquid from a second source can be dispensed into the receiver. The second liquid can be distilled water, thus allowing the user to rinse the instrument without dismounting it or dilute the reagent within the receiver.

Bottle Refilling: Knob A – Closed, Knob B – Open

In this mode, the liquid from a second source can be used to refill the bottle, without dismounting the dispenser.

Designed with ergonomics and intuitive handling in mind, it offers excellent chemical compatibility and enables the achievement of precision in practical laboratory environments. Ultimus also features two product innovations: EasyKnob™ and FlexiNozzle™ that enhance its usability.

What’s in the box?

  1. Dispensing unit
  2. Calibration certificate
  3. Calibration Tool
  4. Bottle Adaptors for all standard reagent bottle neck sizes (28mm – 45mm)
  5. Instruction Manual

Applications

Microlit Ultimus, a bottle dispenser, is more than just a scientific instrument. It has a wide application in standard laboratory environments such as pharmaceuticals, academics, research institutes, healthcare institutions, and the food & beverage industry to dispenser solvents, corrosive acids and other reagents. Ultimus may also be used in the industry as an e-liquid bottle dispenser, essential oils bottle dispenser or a CBD oil bottle dispenser.

With increasing industrial demand, the popularity of Microlit bottle top dispensers is expected to go as more industries discover the top-notch quality, high functionality, and assured improvement in efficiency that the bottle dispenser offers.

Features
Change Volume with EasyKnob™

Change Volume with EasyKnob™

EasyKnob™ is a specially designed volume adjustment knob that allows 180° rotation for easy and effortless volume setting.

Move Effortlessly with a PTFE Piston

Move Effortlessly with a PTFE Piston

A PTFE Piston with an ETP O-Ring facilitates smooth and effortless movement and ensures high chemical compatibility.

Forget Dismounting with Dual Inlet™

Forget Dismounting with Dual Inlet™

MICROLIT ULTIMUS is equipped with an awardwinning patented technology, Dual Inlet™, that enables 4 liquid handling modes without dismounting the dispenser.

Dispense Easily with FlexiNozzle™

Dispense Easily with FlexiNozzle™

FlexiNozzle™ is an adjustable delivery nozzle. It offers a high degree of flexibility, facilitating easy dispensing in demanding laboratory conditions.

Work Flexibly with a 360° Adapter

Work Flexibly with a 360° Adapter

A specially designed Adapter allows 360° rotation, facilitating complete work flexibility.

Model No. Description Vol. Range Increment Accuracy CV
+% +ml +% +ml
ULT-2.5 Ultimus Bottle Top  Dispenser 0.25-2.5ml 0.25-2.5ml 0.05ml 0.5 0.0125 0.2 0.005
ULT-5 Ultimus Bottle Top Dispenser 0.5-5ml 0.05ml 0.1ml 0.5 0.025 0.2 0.01
ULT-10 Ultimus Bottle Top Dispenser 1-10ml 1-10ml 0.2ml 0.5 0.05 0.1 0.01
ULT-30 Ultimus Bottle Top Dispenser 2.5-30ml 2.5-30ml 0.5ml 0.5 0.15 0.1 0.03
ULT-60 Ultimus Bottle Top Dispenser 5-60ml 5-60ml 1.0ml 0.5 0.3 0.1 0.06
ULT-100 Ultimus Bottle Top Dispenser 10-100ml 10-100ml 2.0ml 0.5 0.5 0.1 0.1

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance
with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-5.

Purging or priming is performed to remove the air bubbles from the barrel. For priming, gently pull the piston up and then push down rapidly till the piston hits the base. Repeat this procedure for at least five times. If the problem still persists, please check the telescopic or inlet tube fitment.
Microlit dispensers are compatible with a wide range of reagents/chemicals as the materials of the wetted components of the dispenser (PTFE, Borosilicate glass, FEP, PP) do not react with the most commonly used reagents. For specific reagent compatibility please refer to our Chemical Compatibility Chart
Yes, the bottle dispensers are fully autoclavable at 121 C for 15-20 min at 15 psi. However, do not put the dispenser in the autoclave without disassembly. Disassemble the piston and shaft from the dispenser before autoclaving. The volume-adjustment knob must be kept in an unlocked position. Lastly, re-calibration is necessary after autoclaving. Please refer to the instruction manual for the correct detailed autoclaving procedure.
Set the ml dispenser at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the dispenser is calibrated. If not, please follow the recalibration procedure in the instruction manual.
We recommend rinsing the dispenser with de-ionized or distilled water before and after the use. For detailed maintenance and cleaning of the dispenser, please refer to the product instruction manual.
We recommend maintaining the temperature of the instrument and the reagent between +15 C to +40 C.
The dispenser comes with a 5 set of adaptors of the size between 28, 32, 38,40, and 45mm that will allow the dispenser to be mounted on any standard reagent glass bottle.
For the second bottle, an additional set of four reservoir covers are provided in the sizes 32, 36, 40, and 45 mm.
Yes, to work against the stronger acids, these acids bottle top dispensers are compatible as the wetted components of the dispenser (PTFE, PFA, Borosilicate glass, Zirconia, and FEP) are inert and do not react with them. However, it is strongly advised not to leave the instrument mounted over strong acids as it may cause discoloration or softening of the external material but it will NOT affect its functionality. Please refer to our Chemical Compatibility Chart
Yes, the dispenser can be used as an essential oils dispenser. However, we recommend using the fluids with a maximum viscosity of 500cP.
The dispenser may not be able to aspirate the liquid from the second inlet tube if it is loose. To fix this, unscrew the second inlet and reassemble. Please refer to the instruction manual for the detailed assembling of the second inlet.