• Multiple Offers
    Multiple Offers
  • Support
    Real-Time Support
  • Free Replacement
    1-Year Free Replacement Warranty
  • (732) 321-0852
Bottle Top Dispenser

Scitus

  • Accurate and jam-free dispensing
  • Fully Autoclavable at 121° C, 15psi. for 10-15 mins
  • High chemical compatibility with SpringlessValveTM and PTFE piston
  • Optimized user experience with EasyKnob™ and FlexiNozzle™
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit Scitus is a Bottle Top Dispenser that works on Springless ValveTM Technology. Designed with ergonomics and intuitive handling in mind, it offers excellent chemical compatibility and enables the achievement of precision in practical laboratory environments. Microlit Scitus also features two product innovations: EasyKnob™ and FlexiNozzle™ that enhance its usability.

What’s in the box?

  1. Dispensing unit
  2. Calibration certificate
  3. Calibration Tool
  4. Bottle Adaptors for all standard reagent bottle neck sizes (28mm – 45mm)
  5. Instruction Manual

Applications

Microlit Scitus, a bottle dispenser, is more than just a scientific instrument. It has a wide application in standard laboratory environments such as pharmaceuticals, academics, research institutes, healthcare institutions, and the food & beverage industry to dispenser solvents, corrosive acids, and other reagents. Scitus may also be used in emerging industries as an e-liquid bottle dispenser, essential oils bottle dispenser, Hemp Oil dispenser, and Vape liquid dispenser, in addition to being used as an acids bottle dispenser and solvents bottle dispenser in the laboratory.

With increasing industrial demand, the popularity of Microlit bottle top dispensers is expected to go as more industries discover the top-notch quality, high functionality, and assured improvement in efficiency that the bottle dispenser offers.

Features
Change Volume with EasyKnob™

Change Volume with EasyKnob™

EasyKnob™ is a specially designed volume adjustment knob that allows 180° rotation for easy and effortless volume setting.

Move Effortlessly with a PTFE Piston

Move Effortlessly with a PTFE Piston

A PTFE Piston with an ETP O-Ring facilitates smooth and effortless movement and ensures high chemical compatibility.

Operate Jam-free with Springless Valve™

Operate Jam-free with Springless Valve™

MICROLIT SCITUS comes with an award-winning technology, Springless Valve™, that facilitates smooth and jam-free functioning.

Dispense Easily with FlexiNozzle™

Dispense Easily with FlexiNozzle™

FlexiNozzle™ is an adjustable delivery nozzle. It offers a high degree of flexibility, facilitating easy dispensing in demanding laboratory conditions.

Work Flexibly with a 360° Adapter

Work Flexibly with a 360° Adapter

A specially designed Adapter allows 360° rotation, facilitating complete work flexibility.

Model No. Description Vol. Range Increment Accuaracy CV
+% +ml +% +ml
SCI-2.5 Scitus Bottle Top Dispenser 0.25-2.5ml 0.25-2.5ml 0.05ml 0.5 0.0125 0.2 0.005
SCI-5 Scitus Bottle Top Dispenser 0.5-5ml 0.05-5ml 0.1ml 0.5 0.025 0.2 0.01
SCI-10 Scitus Bottle Top Dispenser 1-10ml 1-10ml 0.2ml 0.5 0.05 0.1 0.01
SCI-30 Scitus Bottle Top Dispenser 2.5-30ml 2.5-30ml 0.5ml 0.5 0.15 0.1 0.03
SCI-60 Scitus Bottle Top Dispenser 5-60ml 5-60ml 1.0ml 0.5 0.3 0.1 0.06
SCI-100 Scitus Bottle Top Dispenser 10-100ml 10-100ml 2.0ml 0.5 0.5 0.1 0.1

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance
with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-5.


Discover precision in liquid handling with Microlit Scitus Bottle Top Dispensers. Our catalogue showcases a range of Bottle dispensers designed for accurate and efficient liquid transfer. Featuring ergonomic design and easy volume adjustment, Microlit Scitus Bottletop dispensers ensure hassle-free dispensing in diverse laboratory settings. From research to diagnostics, trust Microlit Scitus for reliable performance. Download our catalogue now to explore the perfect dispenser for your needs and elevate your liquid handling experience.
Download Catalog


Unlock the full potential of your Microlit Scitus Bottle Top Dispenser with our comprehensive instruction manual. Designed for precision and ease of use, our manual provides step-by-step guidance for accurate liquid handling. From assembly to operation, learn how to optimize performance and ensure reliable dispensing in your laboratory. Download our instruction manual now to explore detailed instructions, troubleshooting tips, and maintenance guidelines.
Download Instruction Manual


Explore the seamless compatibility of Microlit Scitus Bottle Top Dispensers with our convenient compatibility chart. Whether you’re working with acids, bases, solvents, or reagents, our chart simplifies the selection process by detailing the compatibility of our dispensers with various bottle types and sizes. Ensure hassle-free liquid handling in your laboratory by downloading our compatibility chart now.
Download Compatibility Chart

What our Customers are saying

Liquid Handling Products Manufacturer

Dealer Opportunities

Microlit is your one-stop destination for precision liquid handling instruments: Micropipettes, Bottle Top Dispensers, Electronic Burettes, Pipette controllers, Pipette tips, and more. Experience the ease of streamlining your operations and enhancing your brand’s reach with Microlit’s comprehensive suite of offerings.

Product FAQs

Purging or priming is performed to remove the air bubbles from the barrel. For priming, gently pull the piston up and then push down rapidly till the piston hits the base. Repeat this procedure for at least five times. If the problem still persists, please check the telescopic or inlet tube fitment.
Microlit dispensers are compatible with a wide range of reagents/chemicals as the materials of the wetted components of the dispenser (PTFE, Borosilicate glass, FEP, PP) do not react with the most commonly used reagents. For specific reagent compatibility please refer to our Chemical Compatibility Chart
Yes, the Microlit dispensers are fully autoclavable at 121°C for 15-20 min at 15 psi. However, do not put the dispenser in the autoclave without disassembly. Disassemble the piston and shaft from the dispenser before autoclaving. The volume-adjustment knob must be kept in an unlocked position. Lastly, re-calibration is necessary after autoclaving. Please refer to the instruction manual for the correct detailed autoclaving procedure.
Set the ml dispenser at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the dispenser is calibrated. If not, please follow the recalibration procedure in the instruction manual.
We recommend rinsing the Microlit dispenser with de-ionized or distilled water before and after the use. For detailed maintenance and cleaning of the dispenser, please refer to the product instruction manual.
The dispenser comes with a 5 set of adaptors of the size between 28, 32, 38,40, and 45mm that will allow the dispenser to be mounted on any standard reagent glass bottle.
The minimum length of the telescopic inlet tube of the bottle top dispenser is 170mm and is extendable up to 320 mm. We also offer 450mm inlet tube in additional purchase for any specific requirement.
Yes, to work against the stronger acids, these acid bottle top dispensers are compatible as the wetted components of the dispenser (PTFE, PFA, Borosilicate glass, Zirconia, and FEP) are inert and do not react with them. However, it is strongly advised not to leave the instrument mounted over strong acids as it may cause discoloration or softening of the external material but it will NOT affect its functionality. Please refer to our Chemical Compatibility Chart
Yes, Microlit dispenser can function as an essential oil dispenser. However, we recommend using fluids with a maximum viscosity of 500 cP.
The dispenser may not be able to aspirate the liquid if the valve ball is stuck. It might happen due to the negative air pressure while air transportation. However, the following quick troubleshoot can easily be performed:
  • Check whether the Inlet tube is fitted firmly. If not, cut off the tube approx. 1cm from above and refix the tube again.
  • Check whether the ball in the valve system is stuck. Rinse the dispenser with distilled water so as to remove the reagent deposit inside the valve mechanism or Insert a thin wire at the inlet stub and push the ball with very little force to release the stuck valve ball.
Oil Bottle Dispenser

Beatus

with Re-circulation Valve
  • Accurate and jam-free dispensing
  • Re-circulation valve technology to prime instrument without loss of reagent
  • Fully Autoclavable at 121° C, 15psi. for 10-15 mins
  • High chemical compatibility with SpringlessValveTM and PTFE piston
  • Optimized user experience with EasyKnob™ and FlexiNozzle™
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit Beatus is a Bottle Top Dispenser that works on Recirculation Valve and Springless ValveTM Technology. Designed with ergonomics and intuitive handling in mind, it offers excellent chemical compatibility and enables the achievement of precision in practical laboratory environments. Beatus also features two product innovations: EasyKnob™ and FlexiNozzle™ that enhance its usability.

What’s in the box?

  1. Dispensing unit
  2. Calibration certificate
  3. Calibration Tool
  4. Bottle Adaptors for all standard reagent bottle neck sizes (28mm – 45mm)
  5. Instruction Manual

Applications

Microlit Beatus, a bottle dispenser, is more than just a scientific instrument. It has a wide application in standard laboratory environments such as pharmaceuticals, academics, research institutes, healthcare institutions, and the food & beverage industry to dispenser solvents, corrosive acids, and other reagents. Microlit Beatus may also be used in emerging industries as an e-liquid bottle dispenser, essential oils bottle dispenser, Hemp Oil dispenser, and Vape liquid dispenser, in addition to being used as an acids bottle dispenser and solvents bottle dispenser in the laboratory.

With increasing industrial demand, the popularity of Microlit bottle top dispensers is expected to go as more industries discover the top-notch quality, high functionality, and assured improvement in efficiency that the bottle dispenser offers.

Features
Change Volume with EasyKnob™

Change Volume with EasyKnob™

EasyKnob™ is a specially designed volume adjustment knob that allows 180° rotation for easy and effortless volume setting.

Move Effortlessly with a PTFE Piston

Move Effortlessly with a PTFE Piston

A PTFE Piston with an ETP O-Ring facilitates smooth and effortless movement and ensures high chemical compatibility.

Re-direct Liquids with Recirculation Valve

Re-direct Liquids with Recirculation Valve

Recirculation Valve prevents the loss of reagents during purging by re-directing them into the mounted bottle and facilitates bubble free dispensing.

Operate Jam-free with Springless Valve™

Operate Jam-free with Springless Valve™

MICROLIT BEATUS comes with an award-winning technology, Springless Valve™, that facilitates smooth and jam-free functioning.

Dispense Easily with FlexiNozzle™

Dispense Easily with FlexiNozzle™

FlexiNozzle™ is an adjustable delivery nozzle. It offers a high degree of flexibility, facilitating easy dispensing in demanding laboratory conditions.

Work Flexibly with a 360° Adapter

Work Flexibly with a 360° Adapter

A specially designed Adapter allows 360° rotation, facilitating complete work flexibility.

Model No. Description Vol. Range Increment Accuracy CV
+% +ml +% +ml
BEAT-2.5 Beatus Bottle Top Dispenser 0.25-2.5ml 0.25-2.5ml 0.05ml 0.5 0.0125 0.2 0.005
BEAT-5 Beatus Bottle Top Dispenser 0.5-5ml 0.05-5ml 0.1ml 0.5 0.025 0.2 0.01
BEAT-10 Beatus Bottle Top Dispenser 1-10ml 1-10ml 0.2ml 0.5 0.05 0.1 0.01
BEAT-30 Beatus Bottle Top Dispenser 2.5-30ml 2.5-30ml 0.5ml 0.5 0.15 0.1 0.03
BEAT-60 Beatus Bottle Top Dispenser 5-60ml 5-60ml 1.0ml 0.5 0.3 0.1 0.06
BEAT-100 Beatus Bottle Top Dispenser 10-100ml 10-100ml 2.0ml 0.5 0.5 0.1 0.1

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance
with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-5.

What our Customers are saying

Liquid Handling Products Manufacturer

Dealer Opportunities

Microlit is your one-stop destination for precision liquid handling instruments: Micropipettes, Bottle Top Dispensers, Electronic Burettes, Pipette controllers, Pipette tips, and more. Experience the ease of streamlining your operations and enhancing your brand’s reach with Microlit’s comprehensive suite of offerings.

Product FAQs

Purging or priming removes air bubbles from the barrel. To prime, gently pull the piston up and then rapidly push down until it hits the base. Repeat the procedure at least five times. If the problem persists, please inspect the telescopic or inlet tube fittings.
Microlit bottle dispensers are suitable with an extensive range of reagents/chemicals because the dispenser's wetted components (PTFE, Borosilicate glass, FEP, and PP) do not react with the most common reagents. For any specific reagent compatibility please refer to our Chemical Compatibility Chart
Yes, Microlit dispensers are completely autoclavable at 121°C for 15-20 minutes at 15 psi. Yet, do not put the dispenser in the autoclave unless it has been disassembled. Before autoclaving, disassemble the dispenser's piston and shaft. The volume adjustment knob must remain unlocked. At last, re-calibration is required after autoclaving. Please refer to the instruction manual for a detailed autoclaving procedure.
Set the ml dispenser to its nominal volume and dispense distilled water at least five times. Use an analytical/ electronic balance to measure the liquid that has been dispensed. If the mean and CV of the readings fall within the acceptable ISO limits (see specs chart), the dispenser is calibrated. If not, please follow the re-calibration steps outlined in the instruction manual.
We suggest rinsing the Microlit dispenser with deionized or distilled water before and after use. The Microlit product instruction manual contains detailed instructions for maintaining and cleaning the dispenser.
We adjust the piston so that it is smooth and does not require excessive force to dispense. This may result in auto-dispensing after the liquid is aspirated. However, this is not a problem and will not affect the accuracy of the instrument. It is recommended to immediately dispense the liquid after aspiration.
We recommend maintaining the temperature of the instrument and the reagent between +15 C to +40 C.
The Microlit dispenser comes with five sets of adaptors ranging in size from 28, 32, 38, 40, and 45mm, allowing it to be mounted on any standard reagent glass bottle.
The bottle top dispenser's telescopic inlet tube has a minimum length of 170mm and can be extended to 320mm. For any specific requirements, we also offer a 450mm inlet tube as an additional purchase.
Yes, these acid bottle top dispensers can work against stronger acids because the dispenser's wetted components (PTFE, PFA, Borosilicate glass, Zirconia, and FEP) are inert and do not react with them. However, it is highly recommended not to leave the instrument mounted in strong acids, as this can lead to discoloration or softening of the external material but will have no effect on its functionality. Please refer to our Chemical Compatibility Chart
Bottle Dispenser

Ultimus

with Dual Inlet Technology
  • Accurate and jam-free dispensing
  • Rinsing, Dilution, Re-filling and Purging modes with Dual InletTM
  • Recirculation valve technology to prime instrument without loss of reagent
  • Fully Autoclavable at 121° C, 15psi. for 10-15 mins
  • High chemical compatibility with SpringlessValveTM and PTFE piston
  • Optimized user experience with EasyKnob™ and FlexiNozzle™
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit Ultimus is a Bottle Top Dispenser that works on Dual InletTM Technology, Recirculation Valve Technology and Springless ValveTM Technology. The Dual Inlet Technology, patented in the US and EU, enables 4 liquid handling modes – rinsing, dilution, refilling & purging without dismounting the dispenser.

Standard Dispensing: Knob A – Open, Knob B – Closed

In this mode, the dispenser dispenses the liquid normally into the receiver from the bottle it is mounted on.

Purging: Knob A – Closed, Knob B – Closed

In this mode, the liquid is recirculated into the same bottle on which the dispenser is mounted. This process removes the air from the dispenser, without wasting any reagent.

Dilution/Rinsing/Second Liquid Dispensing: Knob A – Open, Knob B – Open

In this mode,the liquid from a second source can be dispensed into the receiver. The second liquid can be distilled water, thus allowing the user to rinse the instrument without dismounting it or dilute the reagent within the receiver.

Bottle Refilling: Knob A – Closed, Knob B – Open

In this mode, the liquid from a second source can be used to refill the bottle, without dismounting the dispenser.

Designed with ergonomics and intuitive handling in mind, it offers excellent chemical compatibility and enables the achievement of precision in practical laboratory environments. Ultimus also features two product innovations: EasyKnob™ and FlexiNozzle™ that enhance its usability.

What’s in the box?

  1. Dispensing unit
  2. Calibration certificate
  3. Calibration Tool
  4. Bottle Adaptors for all standard reagent bottle neck sizes (28mm – 45mm)
  5. Instruction Manual

Applications

Microlit Ultimus, a bottle dispenser, is more than just a scientific instrument. It has a wide application in standard laboratory environments such as pharmaceuticals, academics, research institutes, healthcare institutions, and the food & beverage industry to dispenser solvents, corrosive acids and other reagents. Ultimus may also be used in the industry as an e-liquid bottle dispenser, essential oils bottle dispenser or a CBD oil bottle dispenser.

With increasing industrial demand, the popularity of Microlit bottle top dispensers is expected to go as more industries discover the top-notch quality, high functionality, and assured improvement in efficiency that the bottle dispenser offers.

Features
Change Volume with EasyKnob™

Change Volume with EasyKnob™

EasyKnob™ is a specially designed volume adjustment knob that allows 180° rotation for easy and effortless volume setting.

Move Effortlessly with a PTFE Piston

Move Effortlessly with a PTFE Piston

A PTFE Piston with an ETP O-Ring facilitates smooth and effortless movement and ensures high chemical compatibility.

Forget Dismounting with Dual Inlet™

Forget Dismounting with Dual Inlet™

MICROLIT ULTIMUS is equipped with an awardwinning patented technology, Dual Inlet™, that enables 4 liquid handling modes without dismounting the dispenser.

Dispense Easily with FlexiNozzle™

Dispense Easily with FlexiNozzle™

FlexiNozzle™ is an adjustable delivery nozzle. It offers a high degree of flexibility, facilitating easy dispensing in demanding laboratory conditions.

Work Flexibly with a 360° Adapter

Work Flexibly with a 360° Adapter

A specially designed Adapter allows 360° rotation, facilitating complete work flexibility.

Model No. Description Vol. Range Increment Accuracy CV
+% +ml +% +ml
ULT-2.5 Ultimus Bottle Top  Dispenser 0.25-2.5ml 0.25-2.5ml 0.05ml 0.5 0.0125 0.2 0.005
ULT-5 Ultimus Bottle Top Dispenser 0.5-5ml 0.05-5ml 0.1ml 0.5 0.025 0.2 0.01
ULT-10 Ultimus Bottle Top Dispenser 1-10ml 1-10ml 0.2ml 0.5 0.05 0.1 0.01
ULT-30 Ultimus Bottle Top Dispenser 2.5-30ml 2.5-30ml 0.5ml 0.5 0.15 0.1 0.03
ULT-60 Ultimus Bottle Top Dispenser 5-60ml 5-60ml 1.0ml 0.5 0.3 0.1 0.06
ULT-100 Ultimus Bottle Top Dispenser 10-100ml 10-100ml 2.0ml 0.5 0.5 0.1 0.1

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance
with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-5.

Product FAQs

Purging or priming is a method to remove air bubbles from the barrel. To prime the piston, gently pull it up and then rapidly push down until it hits the base. Repeat this process at least five times. If the problem persists, examine the telescopic or inlet tube fitment.
Microlit bottle dispensers are appropriate with a wide range of reagents/chemicals because the materials used in the dispenser's wetted components (PTFE, Borosilicate glass, FEP, PP) do not react with the most common reagents. For any reagent compatibility please refer to our Chemical Compatibility Chart
Yes, the Microlit dispensers are completely autoclavable at 121°C for 15-20 minutes at 15 psi. But, don't autoclave the dispenser unless it has been disassembled. Before autoclaving the Microlit dispenser, disassemble the piston and shaft. The volume adjustment knob must be kept unlocked. In the end, after autoclaving, it is necessary to re-calibrate. For the correct and detailed autoclaving procedure, please see the instruction manual.
Set the ml dispenser to the appropriate volume and dispense distilled water at least five times. Use an analytical or electronic balance to measure the dispensed liquid. The dispenser is calibrated if the mean and CV readings fall within the acceptable ISO limits (see specs chart). If not, please use the re-calibration procedure described in the instruction manual.
We advise rinsing the Microlit dispenser with deionized or distilled water before and after usage. The product instruction manual contains detailed instructions for maintaining and cleaning the Microlit dispenser.
We recommend maintaining the temperature of the instrument and the reagent between +15 C to +40 C.
The Microlit dispenser comes with five sets of adaptors ranging in size from 28, 32, 38, 40 to 45mm, facilitating it to be mounted on any standard reagent glass bottle.
For the second bottle, an additional set of four reservoir covers are provided in the sizes 32, 36, 40, and 45 mm.
Yes, these acid bottle top dispensers are compatible with stronger acids because the dispenser's wetted components (PTFE, PFA, Borosilicate glass, Zirconia, and FEP) are inert and do not react with them. However, it is highly suggested not to leave the instrument mounted over strong acids, as this can lead to discoloration or softening of the external material but will have no effect on its functionality. Please refer to our Chemical Compatibility Chart
Yes, the dispenser can serve as an essential oil dispenser. However, we suggest that you use fluids with a maximum viscosity of 500cP.
The dispenser may not be able to aspirate the liquid from the second inlet tube if it is loose. To fix this, unscrew the second inlet and reassemble. Please refer to the instruction manual for the detailed assembling of the second inlet.