• Multiple Offers
    Multiple Offers
  • Support
    Real-Time Support
  • Free Replacement
    1-Year Free Replacement Warranty
  • (732) 321-0852
By microlit
View view 143310
Enquire Now

Micropipette Product Guide

What is a micropipette?

A micro pipette is a common yet essential laboratory instrument used to accurately and precisely transfer volumes of liquid in the microliter range. Micropipettes are available in single-channel and multi-channel variants. While the single-channel micropipettes are used in labs that perform research related to molecular biology, microbiology, immunology, cell culture, analytical chemistry, biochemistry and genetics, the multichannel micropipettes are recommended for ELISA (diagnostic test), molecular screening, kinetic studies and DNA amplification.

Components of a micropipette:

Micropipettes are available in different designs and sizes. However, there are certain components that are basic and common to all micropipettes. These include the plunger, digital display, tip cone, tip ejector and grippy. Certain micropipettes are provided with a calibration tool and a micropipette stand as an accessory, Micropipette Diagram:

Pipette Components

Plunger:

The plunger performs the following two functions- 

  1. Volume adjustment:

    Rotate the plunger clockwise/ anticlockwise to decrease/ increase the volume setting. A distinct click sound at every volume change ensures perfect volume setting and prevents any accidental volume change.

  2. Liquid aspiration/ dispensing:

    Press and depress the plunger to aspirate or dispense liquid.

Tip Ejector:

The internal mechanism of the micro pipette does not come in direct contact of the sample/liquid. Instead, a disposable micropipette tip is used to draw the liquid into and dispense from the micropipette. So in order to allow the safe, effortless and quick ejection of tips, micropipettes are provided with a tip ejection system. The tips can be easily removed from the micropipette by pressing the tip ejector button. 

Volume Display:

This shows the volume of the liquid to be aspirated or dispensed.

Tip Cone:

The tip cone provides fitment to the tips. A pipette with a universal tip cone is preferred as it enhances the compatibility of the instrument with most of the standard tips.

Micropipette Uses in Laboratory

Micropipettes are vital in labs for precise liquid handling. Their uses in microbiology and molecular biology are extensive. From measuring tiny liquid volumes to conducting ELISA tests, micropipettes are indispensable. They come in various types, like single-channel or multi-channel, each serving specific lab needs. Their accuracy makes them essential for experiments in genetics, cell culture, and biochemistry.

In laboratories, micropipettes are used for accurate liquid transfer. They are crucial in tasks like DNA amplification and kinetic studies. Different pipette types, including automatic and manual, cater to diverse uses. In microbiology, micropipettes ensure precision, which is key for successful experiments. Their versatility extends to various fields, making them a fundamental tool in any lab setting.

Types of micropipette:

Micropipettes can be classified depending upon:

  • Working Principle:

The plunger performs the following two functions- 

  1. Air Displacement Micropipette:

    This type of micropipette works on the air displacement principle. It consists of a piston that aspirates and dispenses liquid samples as the air pocket moves up and down, respectively. The internal mechanism of the pipette does not come in direct contact of the sample/liquid. Instead, a disposable micropipette tip is used to draw the liquid into and dispense from the pipette.

  2. Positive Displacement Micropipette:

    In these pipettes, the piston comes in direct contact of the sample. The disposable tip in a positive displacement micropipette is a microsyringe composed of a capillary and a piston (movable inner part) which directly displaces the liquid.

  • Operating Mechanism:

  1. Mechanical Micro pipette:

    These pipettes are operated manually based on a piston-shaft spring mechanism.

  2. Electronic Micropipette:

    An electronic micropipette is mostly automated. The aspirating and dispensing of liquid is performed by the one-touch buttons instead of manual plunger pressing and depressing. Electronic pipettes also often enable the user to create custom programs on the device allowing the pipettes to suit diverse application needs.

  • Number of Channels:

  1. Single Channel Micropipette:

    A single-channel micropipette is one that has a single channel to aspirate or dispense the liquid.

  2. Multi-Channel Micropipette:

    A multi-channel micropipette has multiple channels to aspirate or dispense the liquid. The commonly available multi-channel micropipette variants are the 8-channel, 12-channel and 16-channel. Multichannel micropipettes reduce the workload of a single-channel micropipette when working with large volumes of samples.

  • Volume/Capacity:

  1. Fixed Volume Micropipette:

    In a Fixed Volume Micropipette, the volume of liquid to be aspirated or dispensed remains fixed. These micropipettes are used when the same volume of liquid is to be dispensed multiple times.

  2. Variable Volume Micropipette:

    This micropipette comes with a specific minimum and maximum volume range. The volume of the liquid to be aspirated or dispensed can be adjusted (within the instrument’s volume range) depending on the requirement of the user.

Size and Range / Technical Specifications:

Micropipettes are available in different volumes ranging from 0.1 µl to 10,0000 µl. The commonly used variants of single-channel variable volume micropipettes are listed below along with their permissible error limits as specified in the ISO 8655-2 standard.

They are sometimes referred to as P10, P20, P1000, P5000 pipettes based on the maximum volume that can be aspirated/dispensed using the pipette. For instance, a 0.5-10ul Micro pipette may be commonly referred to as a P10 pipette.

Volume Range
(ul)
Classification
Increment
(ul)
Accuracy
(± %)
Accuracy
(±ul)
CV
(± %)
CV
( ± ul)
0.2-2 P2 0.01 2 0.04 1.2 0.024
0.5-10 P10 0.02 1 0.1 0.5 0.05
2-20 P20 0.02 0.8 0.16 0.4 0.08
5-50 P50 0.1 0.8 0.4 0.4 0.2
10-100 P100 0.2 0.6 0.6 0.2 0.2
20-200 P200 0.2 0.6 1.2 0.2 0.4
100-1000 P1000 1.0 0.6 6 0.2 2
500-5000 P5000 10.0 0.6 30 0.2 10
1000-10000 P10000 20.0 0.6 60 0.2 20

 

How does a micropipette work?

Air displacement micropipettes operate by piston-driven air displacement. When the piston is pressed downwards, the air within the sleeve of the micropipette gets expelled out due to the force of which the liquid present in the tip of the micropipette also gets removed.

When the piston moves upwards, a vacuum is created in the space left vacant by the piston. This causes the air from the tip to rise in order to fill the vacant space, and the tip air is then replaced by the liquid, which is drawn up into the tip.

Positive displacement micropipettes operate by piston-driven displacement. The piston in a positive displacement micropipette is in direct contact with the liquid. When the piston is pressed downwards, the liquid which is present in the sleeve of the micropipette also moves downwards and gets removed through the tip. When the piston is pulled upwards, it also draws the liquid along with it in the upward direction.

  1. Using an Air Displacement Micro pipette:

    Precise measurement of liquid depends on the correct micropipette usage. The air displacement micropipettes work on the common air displacement principle. A plunger is depressed by the thumb and as it is released, the liquid is drawn into a disposable tip. When the plunger is pressed again, the liquid is dispensed. In between these steps, there are several small steps that help in making the liquid dispensing process more precise.

    Correct Pipetting methods

    Position 1 In this, the micropipette is at rest position. Press fit a tip to the micropipette without directly touching the tip.
    Position 2 In this, the plunger is depressed till the first stop. To aspirate the liquid in the tip, press the plunger to the first stop. Immerse the pipette tip vertically in the liquid.
    Release the plunger Slowly release the plunger while the tip is immersed. The liquid will be aspirated into the pipette tip.
    The liquid is filled in the tip as per the preset micropipette volume.
    Position 3 Depress the plunger To dispense the liquid, place the tip on the inner wall of the receiving vessel at a steep angle.
    Slowly press the plunger to the first stop to dispense the liquid.
    To empty the tip completely, press the plunger to the second stop.
    Wipe the tip on the inner wall while taking the tip out of the vessel.

     

    Some micropipettes deliver a fixed volume of liquid. However, the majority are adjustable with the variable volume setting. Variable volume micropipette comes with different ranges and upper & lower limits of measurement. In such cases, the error percentage may vary as per the measured liquid. Trying to dispense less than the lower value of the range will result in inaccurate liquid measurements whereas trying to dispense over the upper range will completely fill the tip and allow the liquid to enter into the pipette body.

  2. Cleaning, maintenance and storage of a micropipette

    The care and maintenance of a micropipette is an important routine in laboratories. Implementing a proper maintenance schedule can reduce the cost of a new purchase of this expensive equipment. Cleaning the micropipette takes time, focus and practice; otherwise, the micropipette can be damaged. So, it is important to handle the micropipette carefully while cleaning. The following is a comprehensive guide for proper cleaning of micropipettes.

    External Cleaning: Most of the pipette can be cleaned externally with typical laboratory cleaning agents, soaps or alcohol. To ensure full sterilization, let the cleaning solution sit on the micropipette for 10-15 min before wiping it off.

    Internal Cleaning: Cleaning the interior of the micropipette can be more time-consuming because it requires full disassembly. Also, every part of the micropipette will need to be cleaned properly depending on the liquid used in sampling.
    – Refer to the instructions manual for a specific direction of the micropipette
    – Use a cotton swab with a cleaning solution and distilled water
    – Lightly grease the pistons with the lubricant provided upon purchase
    – Reassemble all parts and check to ensure the micropipette operates smoothly

    Contamination Cleaning: If the micropipette becomes contaminated with a known substance, there are specific cleaning steps that must be taken depending on the type of substance. The above cleaning routine will not be sufficient if the micropipette is cross-contaminated.

    Solution Types Process to clean
    For aqueous solutions, organic solvents and proteins Rinse the contaminated parts with distilled water or 70 percent ethanol and air dry at approx 60°F temperature.
    For infectious liquids Autoclave the lower section at a temperature of 120°C for 15-20 minutes then allow it to return at room temperature before reassembling.
    For radioactive substances Place the pipette in a solution like Decon and then rinse and air dry.
    For nucleic acids Boil the lower parts of the micropipette in glycine/ HCI buffer (pH2) for 10 minutes, rinse with distilled water, and air dry.

     

    A well-maintained and clean pipette ensures lab safety from hazardous solutions. It makes the pipette more accurate, reliable, long-lasting and reduces the cost of sampling.

    Proper storage of micropipettes is as important as cleaning and calibrating them. The micropipette and its accessories should be stored in a clean, cool and dry place. The storage place should have a temperature ranging from -20 °C to 50 °C (from -4 °F to 120 °F) with relative humidity between 5% and 95%. Another point to be remembered is that the instrument should be stored in an upright position. To store pipettes, Microlit recommends the use of its carousel stand, Microlit Faveo.

What are the different pipetting techniques used?

The frequently used pipetting techniques include forward pipetting and reverse pipetting. Before we understand these techniques in detail, the general instructions and micropipette diagram of pipetting listed below would be noteworthy.

  1. Microlit MicropipettesPress and release the plunger slowly, at all times, particularly when working with high-viscosity reagents/solutions. Make sure that the plunger does not snap.
  2. Make sure the tip is firmly attached to the tip cone.
  3. Before starting your experiment, fill and empty the tip 2-3 times with the reagent or solution that you will be pipetting.
  4. Hold the micropipette in an upright position while aspirating. The Grippy must rest on your index finger.
  5. Make sure that the tips, the micropipette and the reagent/solution are at the same temperature.

Forward Pipetting Technique:

  1. Forward Pipetting TechniqueTo aspirate the liquid in the tip, press the plunger to the first stop. Immerse the pipette tip vertically in the liquid.
  2. Slowly release the plunger while the tip is immersed. The liquid will be aspirated into the pipette tip.
  3. To dispense the liquid, place the tip on the inner wall of the receiving vessel at a steep angle
  4. Slowly press the plunger to the first stop to dispense the liquid.
  5. To empty the tip completely, press the plunger to the second stop.
  6. Wipe the tip on the inner wall while taking the tip out of the vessel.

Reverse Pipetting Technique:

The reverse technique is suitable for dispensing reagents/solutions that have high viscosity or a tendency to foam easily. It is also recommended for dispensing very small volumes.

  1. Reverse Pipetting Technique:To aspirate the liquid in the tip, press the plunger to the second stop and immerse the pipette tip vertically in the liquid.
  2. Slowly release the plunger while the tip is immersed. The liquid will be aspirated into the pipette tip.
  3. To dispense the liquid, place the tip on the inner wall of the tube at a steep angle.
  4. Slowly press the plunger to the first stop.
  5. Wipe the tip on the inner wall while taking the tip out of the vessel.

Note: Residual liquid remains in the tip. This does not belong to the dispense volume.

How to choose the right micropipette?

As micropipettes can be used for a number of applications, the dilemma one faces is how to choose the right micropipette while handling a specific task.

For this, you can follow our simple, stepwise guide. The preliminary step includes noting down the details of the experiment you are going to perform with the micropipette. This should ideally include the number of samples, the volume to be transferred, the number of replicates, whether sterile conditions are required and so on. Making a comprehensive list in this manner will make the process of deciding which micropipette to use easier.

  • Selecting the Type of Micropipette:

Types of  Micropipettes – Air Displacement Micropipettes and Positive Displacement Micropipettes. You can choose the right one by matching their applications to the experiment you wish to perform.

  • Next Steps:

After choosing the correct type, let’s look at the subtypes available based on criteria like the volume to be handled, quality of tips, manual or electronic pipettes, etc. This is where the more minute details regarding the experiment will come in handy.

  1. An adjustable micropipette or a fixed micropipette:

    You can either use a micropipette whose volume is already fixed or one whose volume can be adjusted as per requirement. If you regularly use a single volume such as 100 µl for your experiments, go for a fixed volume pipette like MICROLIT RBO Fixed Volume (Single Channel). If your experiment entails you working with a range of volumes, choose the variable or adjustable pipette, like MICROLIT RBO Variable Volume (Single Channel or Multichannel).

  2. The volume to be handled:

    As a standard rule, it is better to choose the smallest pipette capable of handling the required volume because when the set volume is close to the minimum capacity of the micropipette, the accuracy and precision of the readings decrease.

    1. Single channel or multichannel micropipettes:

      This decision can be made based on the number of samples or replicates you are working with. Single channel micropipettes like the MICROLIT RBO Single Channel (Fixed Volume and Variable Volume) are used when the number of samples is less whereas a large number of samples or well plates can be easily handled by multichannel micropipettes like the MICROLIT RBO Multichannel (8-channel and 12-channel).

  3. Micropipette Tips:

    Once you’ve selected your micropipette, this is the next crucial decision to make. Micropipette Tips can be graduated or not graduated, universal or pipette specific, with a filter or without filter, sterile or non-sterile etc. If the experiment requires sterile, aseptic conditions, one should use filtered and sterile tips. Universal tips can be used for a wide range of pipettes. It is also important to match the capacity of the tip with the capacity of the micropipette before use.

  4. Accuracy with specific tolerance:

    Micropipettes are designed to operate with accuracies within a few percent (generally <5%) of the intended value for the volume. Make sure your micropipette provides the same accuracy as you need for your sampling.

How is a micropipette calibrated?

Micropipette calibration is a very important part of any laboratory’s routine for accurate and precise pipetting results. To ensure the accuracy of sampling, it is important to check the pipette calibration every month or in a few months’ gap. Executing a proper micropipette calibration according to ISO 8655 standards requires special ambient conditions. Factors such as air pressure, humidity, temperature and even altitude affect the pipetting results. The below text explains the required material or equipment and all the steps that you need to perform and check the calibration of a micropipette.

Here is a list of things that you will need in order to calibrate a micropipette:

  • Micropipette that needs to be calibrated & tips
  • Distilled Water
  • Clean Beaker
  • Thermometer
  • Distilled Water Density Chart with Temperature
  • Semi-Micro Balance with a readability of at least 0.0001 g
  • Notebook to write down the results
  • Calculator

How to calibrate a pipette using a balance:

  1. Leave the distilled water out for 15-20 minutes to ensure a consistent temperature.
  2. Use the thermometer to measure the temperature of the distilled water.
  3. Place empty and clean the beaker on the balance.
  4. Take the beaker’s weight.
  5. Ensure the micropipette is clean and ready to function.
  6. When filling the micropipette up to the volume that will be calibrated (1ml, for example) with the distilled water, make sure air bubbles are not created in the flask and in the micropipette.
  7. Dispense the distilled water in the beaker using the micropipette.
  8. Use the balance to measure the distilled water’s weight.
  9. Repeat the process 5-10 times at least and note each measurement.
  10. Use the formula V = W * Z to calculate the volume dispensed by the pipette.
    W is the weight of the distilled water
    Z is the “conversion factor based on the density of the water” and
    V is the calculated volume of dispensed water
    The temperature of the water determines its density, which is why it is important to keep the water temperature as constant as possible. Skip if you have the software that automatically does that.
  11. Average the results. If you did 10 tests, divide the sum of the 10 tests by 10.
  12. The average weight of the distilled water is the  W in the equation. You can now solve the equation manually, or use the software.
  13. The next step is determining the pipette’s accuracy, manually or via software. If you have to do it manually, use the formula A = 100 x Vavg/V0
    A stands for Accuracy.
    Vavg is the average calculated volume.
    V0 is the value assigned for the pipette to dispense.
    It is recommended that the value should be between 99 and 101%.
  14. Record the results. If the micropipette is properly calibrated, you can use it. If the results are consistently wrong, do not use the pipettes or fix them before using it again.

How to sterilize a micropipette?

  • The micropipettes can be sterilized by autoclaving them at 121°C (252°F) and 15 PSI for a duration of 15-20 minutes.
  • No special preparation is needed.
  • You may use steam sterilization bags if needed. After autoclaving, the micropipette must be cooled to room temperature for at least two hours. Before pipetting, make sure that the instrument is dry.
  • It is recommended to check the calibration after every sterilization cycle to achieve the best possible precision and accuracy.

What are micropipette starter kits? How are they beneficial during lab setup?

A micropipette starter kit is the most convenient and cost-effective collection of pipetting essentials. It includes a set of micropipettes with different volume ranges, micropipette tips that can be used in given micropipettes and some other accessories for an efficient sampling process.

A micropipette starter kit is beneficial as it saves the time of selecting the micropipette and the compatible tips which can be used with it. Microlit Micropipette Starter Kit combines 4 single channel pipettes to cover the complete pipetting range (0.5-10ul pipette, 10-100ul pipette, 100-1000ul pipette, 1-10ml pipette). The micropipette kit also includes a sleek carousel stand and boxes of compatible tips for each pipette so that one does not have to go looking for the right tips.

When is micropipette calibration required?

In order to maintain the quality of sampling results, the micropipettes must be in good condition and properly calibrated. Normally, the interval at which a micropipette needs to be calibrated depends on many factors:

  1. Frequency of pipette use
  2. Type of liquid dispensed by the pipettes
  3. Handling & care of pipette
  4. Pipette applications that require superior accuracy also demand more frequent calibration

Regulations and standards published by organizations such as the FDA and ASTM International provide minimum requirements to ensure the quality of laboratory testing results. Regulations specify that all laboratory instruments used in sampling & production including micropipettes must be routinely calibrated at suitable intervals.

In the same series, the Clinical and laboratory standards institute (CSLI) has provided the guidelines for single and multi-channel micropipettes that specify these micropipettes must be calibrated every 3 to 6 months. And a minimum of two volumes must be tested with 10 replicas at both nominal and lowest settings.

Establishing an appropriate calibration frequency minimizes the chances of incorrect liquid delivery in the laboratory and ensures traceability, accountability and confidence in the results.

Applications/fields where micropipettes can be used

Micropipettes are generally used in microbiology, chemistry, and medical testing laboratories for the accurate and precise transfer of samples. While the single-channel micropipettes are used in labs that perform research related to molecular biology, microbiology, immunology, cell culture, analytical chemistry, biochemistry and genetics, the multichannel micropipettes are recommended for ELISA (diagnostic test), molecular screening, kinetic studies and DNA amplification.

Some of the major fields where micropipette is widely used are:

  1. Pharmaceuticals
  2. Health Care
  3. Food & Beverage
  4. Environmental Monitoring
  5. Academic & Research Institutes
  6. Diagnostic Kits
  7. Life Sciences

Benefits of using a micropipette

A micropipette is a reliable device to dispense precise quantities of liquid. It increases the performance of the testing efficiently. Some other benefits of using a micropipette are listed below:

  1. Time-Saving
  2. Ergonomics
  3. Accuracy & Precision
  4. Ease of Use

Where do we get the best micropipette for the lab?

Every lab technician wants a micropipette that is ergonomically designed, aesthetically presentable and provides accurate and precise measurement values. Selecting the best micropipette can be a challenging task as the market is full of micropipettes that appear to be good but do not provide reliable test results. Before going with any micropipette brand, it is important to ensure some points that can save you from wrong pipette purchasing:

– Is the micropipette able to handle your pipetting range of liquid?
– Does your micropipette have a universal tip cone for handling all kinds of tips?
– Is your micropipette autoclavable at the required standard temperature?
– Does your micropipette have smooth and comfortable handling?
– Is your micropipette calibrated for precise dispensing?
– Is the accuracy and precision in readings offered by the micropipette in accordance with the ISO standards?

The above points ensure your right micropipette purchasing which will work for a long time and improve the liquid handling activities in your laboratory.

Microlit designs and develops high-precision liquid handling instruments for leading laboratories around the world. It offers an advanced and innovative micropipette range that facilitates remarkable user experience in practical laboratory environments.

Types of micropipette

FAQs/Troubleshooting:

Which pipette tips can I use with the micropipette?

It depends on your micropipette, if your micropipette has a universal tipcone, you can use it with all international tips as per your micropipette volume range.

How should I sterilize the pipette?

You can sterilize your micropipette if it is autoclavable. If you use your micropipette for sensitive and hazardous liquid sampling, the sterilization process is required to clean your micropipette. Check your micropipette manual to know the maximum temperature and time duration for the sterilization process. Refer to the ‘Contamination Cleaning’ section to know how to sterilize your micropipette easily as per dispensed liquid in the sampling.

How can I check whether the micropipette is calibrated?

It is advisable that every day when you start the pipetting in the lab, check your micropipette for its reading correctness. For this, set the micropipette at the nominal volume and dispense distilled water at least 5 times. Measure the dispensed liquid volume on the electronic balance. If the mean of your readings is within the ISO standard limit, the micropipette is calibrated. If not, calibrate your micropipette and check it again.

How often do I need to calibrate the micropipette?

Generally, it depends on how often your micropipette is used for sampling. For normal use of a micropipette, it should be checked every 3 or 6 months for calibration. As per ISO 8655 standard, it is recommended to get your micropipette calibrated annually.

How do you set the volume on a micropipette?

A small display with 3 number volume range is given on the body of every micropipette. On a fixed volume micropipette, it is a fixed volume range. On the variable volume micropipette, you can adjust it within the given volume range as per your required volume sampling. To change the volume range numbers, use the rotational dial given at the top of the micropipette plunger or refer to the manual to know how to change the volume of the micropipette.

Why should you avoid touching the micropipette tips?

Touching the micropipette tip can cause the liquid to stick to the outside of the tip. The heat transferred from your hands to the tips can affect the delivery of volumes. It also increases the risk of cross-contamination in the laboratory. So, it is recommended to handle the tips only with the micropipette.

What is the largest source of pipetting problems?

Human error is the largest source of pipetting problems which is caused by touching tips, handling micropipettes improperly, etc.

What happens if you release the micropipette plunger too fast?

If the micropipette plunger is released too fast, you may face the issue of less draw-up and dispensing of liquid.

For more information regarding Microlit Products, drop a mail to info-usa@microlit.com.

Enquire Now