  • Universal Tipcone – compatible with internationally accepted tips. Works best with Microlit Pipette Tips
  • Lightweight with soft grip for utmost user comfort
  • Fully autoclavable at 121° C, 15psi. for 10-15 mins
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit RBO Single Channel Variable Volume Micropipette is a High Precision Micropipette that is designed with ergonomics in mind. It facilitates remarkable user experience and impeccable accuracy in practical laboratory environments. The product is highly recommended for Molecular biology, Microbiology, Immunology, cell culture, Analytical Chemistry, Biochemistry, Genetics etc.

 

What’s in the box?

  1. Microlit Micropipette
  2. 3-4 compatible tips
  3. Calibration Tool
  4. Micropipette holder
  5. Calibration Certificate
  6. User guide
Features
Adjust Volume Easily with Plunger

Adjust Volume Easily with Plunger

The Plunger has been carefully designed with a high quality spring mechanism to ensure snag free and soft movement.

Use Various Tips with a Universal Tipcone

Use Various Tips with a Universal Tipcone

A Universal Tipcone enhances the compatibility of the instrument and enables it to easily work with most of the internationally accepted standard tips. However, Microlit tips are recommended.

Set the Volume with Perfection

Set the Volume with Perfection

A soft click sound at every increment ensures perfect volume setting and prevents any accidental changes.

Store Safely with a Holder

Store Safely with a Holder

The instrument includes a Holder that enables easy, efficient and safe storage.

Eject Tips Easily with a Tip Ejector

Eject Tips Easily with a Tip Ejector

Tip Ejector enables easy tip ejection and comfortable access to bottles and tubes with narrow necks.

Work with a Good Grip

Work with a Good Grip

A specially designed large Grippy provides a good grip and great ease of use while operation

Model No. Vol. Range(uL) Increment(uL) Accuaracy CV
+% +uL +% +uL
RBO-2 0.2-2.0ul 0.002 2 0.04 1.2 0.024
RBO-10 0.5-10ul 0.02 1 0.1 0.5 0.05
RBO-20 2-20ul 0.02 0.8 0.16 0.4 0.08
RBO-50 5-50ul 0.1 0.8 0.4 0.4 0.2
RBO-100 10-100ul 0.2 0.6 0.6 0.2 0.2
RBO-200 20-200ul 0.2 0.6 1.2 0.2 0.4
RBO-1000 100-1000ul 1.0 0.6 6 0.2 2
RBO-5000 0.5-5ml 10.0 0.6 30 0.2 10
RBO-10000 1-10ml 20.0 0.6 60 0.2 20

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-2.

What our Customers are saying

Product FAQs

Microlit micropipettes have a universal tip and are compatible with standard universal-fit tips. However, we recommend using Microlit ProTips for the best results.
The pipette is fully autoclavable at 121 C for 15-20 mins at 15 psi.
All pipettes are calibrated as per the ISO 8655 norms, which confirms the accuracy and precision of the liquid handling instruments. However, it is suggested to re-calibrate or get your pipette once in 6 months if it is used regularly.
Set the pipette at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the pipette is calibrated. If not, please follow the recalibration procedure in the instruction manual.
Yes, the pipette is supplied with few sample tips only. However, Microlit ProTips are available in racked, reloads, and bulk packaging for additional purchases.
As per the ISO 8655, it is recommended to get your pipette checked annually. However, based on the usage the pipettes can be re-checked every 3 or 6 months.
It is a good practice to pre-rinse the tip, especially while working with the liquids with high vapor pressure, and every time the tip is changed or the volume of the pipette is changed. Pre-rinsing reduces the capillary effect in low volume pipettes and it neutralizes the temperature of the tip with the sample in high volume pipette tips. Thereby, increasing the chances of the accuracy of an experiment.
The best technique for pipetting any viscous/foaming liquid is the Reverse Pipetting technique. To start with, set the desired volume and depress the plunger till the SECOND step. Immerse the tip inside the liquid and slowly release the plunger. Depress the plunger till the FIRST step only to get the desired volume. The residual (blow-out) volume is discarded. For different pipetting technique, please refer to the instruction manual.
Use of low retention tips is suggested while working with detergents, foaming liquids as well as viscous solutions. Due to its hydrophobicity and low adhesion property, the surface contact between the tip and liquid is less. Thereby, reducing the loss of valuable reagents. Please find Microlit ProTip™ low retention tips in the Tips section.
The design of 5ml and 10ml tip cones is different for each manufacturer and so universal-fit tips will not work. To ensure compatibility, please refer to Microlit ProTip™ low retention tips in the Tips section.

Fixed Volume

  • Universal Tipcone – compatible with internationally accepted tips. Works best with Microlit Pipette Tips
  • Lightweight with soft grip for utmost user comfort
  • Fully autoclavable at 121° C, 15psi. for 10-15 mins
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit RBO Single Channel Fixed Volume Micropipette is a High Precision Micropipette that is designed with ergonomics in mind. It facilitates remarkable user experience and impeccable accuracy in practical laboratory environments. The product is highly recommended for Molecular biology, Microbiology, Immunology, cell culture, Analytical Chemistry, Biochemistry, Genetics etc.

 

What’s in the box?

  1. Microlit Micropipette
  2. 3-4 compatible tips
  3. Calibration Tool
  4. Micropipette holder
  5. Calibration Certificate
  6. User guide
Features
Use Various Tips with a Universal Tipcone

Use Various Tips with a Universal Tipcone

A Universal Tipcone enhances the compatibility of the instrument and enables it to easily work with most of the internationally accepted standard tips.

Work with a Good Grip

Work with a Good Grip

A specially designed large Grippy provides good grip and great ease of use while operating.

Store Safely with a Holder

Store Safely with a Holder

The instrument includes a Holder that enables easy, efficient and safe storage.

Eject Tips Easily with a Tip Ejector

Eject Tips Easily with a Tip Ejector

An in-built, streamlined Tip Ejector enables easy tip ejection and comfortable access to bottles and tubes with narrow necks.

Model No. Vol. Range(uL) Accuaracy CV
+% +uL +% +uL
RBO-F-1 1.0 5 0.05 5 0.05
RBO-F-2 2.0 4 0.08 2 0.04
RBO-F-5 5.0 2 0.1 1 0.05
RBO-F-10 10.0 1 0.1 0.5 0.05
RBO-F-20 20.0 0.8 0.16 0.4 0.08
RBO-F-25 25.0 0.8 0.2 0.4 0.1
RBO-F-50 50.0 0.8 0.4 0.4 0.2
RBO-F-100 100.0 0.6 0.6 0.2 0.2
RBO-F-200 200.0 0.6 1.2 0.2 0.4
RBO-F-250 250.0 0.6 1.5 0.2 0.5
RBO-F-500 500.0 0.6 3 0.2 1
RBO-F-1000 1000.0 0.6 6 0.2 2
RBO-F-2000 2000.0 0.6 12 0.2 4
RBO-F-5000 5000.0 0.6 30 0.2 10
RBO-F-10000 10000.0 0.4 40 0.2 20

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-2.

What our Customers are saying

Product FAQs

Microlit micropipettes have a universal tip and are compatible with standard universal-fit tips. However, we recommend using Microlit ProTips for the best results.
The pipette is fully autoclavable at 121 C for 15-20 mins at 15 psi.
All pipettes are calibrated as per the ISO 8655 norms, which confirms the accuracy and precision of the liquid handling instruments. However, it is suggested to re-calibrate or get your pipette once in 6 months if it is used regularly.
Set the pipette at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the pipette is calibrated. If not, please follow the recalibration procedure in the instruction manual.
Yes, the pipette is supplied with few sample tips only. However, Microlit ProTips are available in racked, reloads, and bulk packaging for additional purchases.
As per the ISO 8655, it is recommended to get your pipette checked annually. However, based on the usage the pipettes can be re-checked every 3 or 6 months.
It is a good practice to pre-rinse the tip, especially while working with the liquids with high vapor pressure, and every time the tip is changed or the volume of the pipette is changed. Pre-rinsing reduces the capillary effect in low volume pipettes and it neutralizes the temperature of the tip with the sample in high volume pipette tips. Thereby, increasing the chances of the accuracy of an experiment.
The best technique for pipetting any viscous/foaming liquid is the Reverse Pipetting technique. To start with, set the desired volume and depress the plunger till the SECOND step. Immerse the tip inside the liquid and slowly release the plunger. Depress the plunger till the FIRST step only to get the desired volume. The residual (blow-out) volume is discarded. For different pipetting technique, please refer to the instruction manual.
Use of low retention tips is suggested while working with detergents, foaming liquids as well as viscous solutions. Due to its hydrophobicity and low adhesion property, the surface contact between the tip and liquid is less. Thereby, reducing the loss of valuable reagents. Please find Microlit ProTip™ low retention tips in the Tips section.
The design of 5ml and 10ml tip cones is different for each manufacturer and so universal-fit tips will not work. To ensure compatibility, please refer to Microlit ProTip™ low retention tips in the Tips section.

Multi-channel

8 and 12 channel micropipettes
  • Universal Tipcone – compatible with internationally accepted tips. Works best with Microlit Pipette Tips
  • Lightweight with soft grip for utmost user comfort
  • Fully autoclavable at 121° C, 15psi. for 10-15 mins
  • Calibration certificate provided – Conforms to ISO 8655 standards
  • Certifications – ISO 9001, ISO 13485, ISO 17025, CE
See More See Less

Microlit RBO Multichannel Micropipettes are High Precision Micropipettes designed with ergonomics in mind. They facilitate remarkable user experience and impeccable accuracy in practical laboratory environments. The multichannel pipette is offered in both 8 and 12 channel. The product is highly recommended for ELISA (Diagnostic Test), Molecular Screening, Kinetic Studies, DNA Amplification etc.

 

What’s in the box?

  1. Microlit Multichannel Micropipette
  2. 3-4 compatible tips
  3. Calibration Tool
  4. Micropipette holder
  5. Calibration Certificate
  6. User guide
Features
Adjust Volume Easily with Plunger

Adjust Volume Easily with Plunger

The Plunger has been carefully designed with a high quality spring mechanism to ensure snag free and soft movement. Simply turn it to adjust the instrument’s volume comfortably.

Use Various Tips with a Universal Tipcone

Use Various Tips with a Universal Tipcone

A Universal Tipcone enhances the compatibility of the instrument and enables it to easily work with most of the internationally accepted standard tips.

Set the Volume with Perfection

Set the Volume with Perfection

A soft click sound at every increment ensures perfect volume setting and prevents any accidental changes. It also facilitates singlehanded operation.

Work with a Good Grip

Work with a Good Grip

A specially designed large Grippy provides good grip and great ease of use while operating.

Store Safely with a Holder

Store Safely with a Holder

The instrument includes a Holder that enables easy, efficient and safe storage.

Eject Tips with a Sequential Tip Ejector

Eject Tips with a Sequential Tip Ejector

A specially designed Sequential Tip Ejector and Tip Ejection Knob facilitate easy and effortless tip ejection, single-handedly.

Model No. Vol. Range(uL) Increment(uL) Accuaracy CV
+% +uL +% +uL
RBO-MCA-8/10
RBO-MCA-12/10
0.5-10ul 0.02 1.6 0.16 1 0.1
RBO-MCA-8/20
RBO-MCA-12/20
2-20ul 0.02 0.8 0.16 0.4 0.08
RBO-MCA-8/50
RBO-MCA-12/50
5-50ul 0.1 0.8 0.4 0.4 0.2
RBO-MCA-8/100
RBO-MCA-12/100
10-100ul 0.2 0.8 0.8 0.3 0.3
RBO-MCA-8/200
RBO-MCA-12/200
20-200ul 0.2 0.8 1.6 0.3 0.6
RBO-MCA-8/300
RBO-MCA-12/300
40-300ul 0.2 0.8 2.4 0.3 0.9

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance with the nominal capacity (or maximum volume) indicated on the instrument. These are obtained by using the instrument with distilled water at equilibrium, the ambient temperature of 20 °C while operating it smoothly and steadily. The error limits are in accordance with DIN EN ISO 8655-2.

What our Customers are saying

Product FAQs

Microlit micropipettes have a universal tip and are compatible with standard universal-fit tips. However, we recommend using Microlit ProTips for the best results.
The pipette is fully autoclavable at 121 C for 15-20 mins at 15 psi.
All pipettes are calibrated as per the ISO 8655 norms, which confirms the accuracy and precision of the liquid handling instruments. However, it is suggested to re-calibrate or get your pipette once in 6 months if it is used regularly.
Set the pipette at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the pipette is calibrated. If not, please follow the recalibration procedure in the instruction manual.
Yes, the pipette is supplied with few sample tips only. However, Microlit ProTips are available in racked, reloads, and bulk packaging for additional purchases.
As per the ISO 8655, it is recommended to get your pipette checked annually. However, based on the usage the pipettes can be re-checked every 3 or 6 months.
It is a good practice to pre-rinse the tip, especially while working with the liquids with high vapor pressure, and every time the tip is changed or the volume of the pipette is changed. Pre-rinsing reduces the capillary effect in low volume pipettes and it neutralizes the temperature of the tip with the sample in high volume pipette tips. Thereby, increasing the chances of the accuracy of an experiment.
The best technique for pipetting any viscous/foaming liquid is the Reverse Pipetting technique. To start with, set the desired volume and depress the plunger till the SECOND step. Immerse the tip inside the liquid and slowly release the plunger. Depress the plunger till the FIRST step only to get the desired volume. The residual (blow-out) volume is discarded. For different pipetting technique, please refer to the instruction manual.
Use of low retention tips is suggested while working with detergents, foaming liquids as well as viscous solutions. Due to its hydrophobicity and low adhesion property, the surface contact between the tip and liquid is less. Thereby, reducing the loss of valuable reagents. Please find Microlit ProTip™ low retention tips in the Tips section.
The design of 5ml and 10ml tip cones is different for each manufacturer and so universal-fit tips will not work. To ensure compatibility, please refer to Microlit ProTip™ low retention tips in the Tips section.