• Multiple Offers
    Multiple Offers
  • Support
    Real-Time Support
  • Free Replacement
    1-Year Free Replacement Warranty
  • (732) 321-0852

NERO 4-Micropipette Starter Kit

  • 4 Microlit Lab Adjustable Micropipettes (2-20ul, 20-200ul, 100-1000ul, 1-10ml)
  • Compatible tip boxes/packets included
  • Universal Tipcone – compatible with most internationally accepted tips
  • Achieve high precision with uAir™ technology
  • Calibrate efficiently in one shot with UniCal™ technology 
  • Lightweight with a soft grip for utmost user comfort
  • Different Color Coding on top for Easy Identification
  • Fully autoclavable at 121° C, 15psi. for at least 15 mins
  • Calibration certificate provided – Conforms to ISO 8655 standards
See More See Less

Microlit NERO Micropipette Starter Kit combines 4 single channel pipettes to cover the complete pipetting range (2-20ul pipette, 20-200ul pipette, 100-1000ul pipette, 1-10ml). The NERO micropipette kit also includes a beautiful carousel stand and boxes of compatible tips for each pipette so that you do not have to go looking for the right tips.

Each of the four Microlit NERO Single Channel Variable Volume Micropipettes are high precision adjustable micropipettes with state-of-the-art technology such as UniCal™ and Air™ that will ensure great precision and convenience for our lab users. These innovative and patented technologies have been developed by our in-house product design engineers. The product is highly recommended for pathology, microbiology, and diagnostic testing labs where precise small volume pipetting is critical.

What’s in the box?

  1. 4 Microlit Adjustable Volume Pipettes (2-20ul, 20-200ul, 100-1000ul, 1-10ml)
  2. 1 carousel pipette stand
  3. R-200-NS-W (upto 200ul) pipette tips (box of 96)
  4. R-1000-NS-W (upto 1000ul) pipette tips (box of 96)
  5. B-10000-NS-T-50 (upto 10 ml) pipette tips (Pkt of 50 Tips)
  6. Calibration Tools
  7. Micropipette holders
  8. Calibration Certificates
  9. Instruction Manuals
Features
Achieve precision with uAir™ technology

Achieve precision with uAir™ technology

The design of Microlit NERO ensures minimum dead air space between the piston and the liquid in the tip. This reduces air compression and enables the user to achieve precision in practical lab conditions.

Calibrate Efficiently with UniCal™ Technology

Calibrate Efficiently with UniCal™ Technology

We have introduced a unique calibration mechanism/tool which allows quick in-lab calibration in a single operation WITHOUT disengaging the digits from the plunger mechanism.

Eject Tips Easily with our Tip Ejector

Eject Tips Easily with our Tip Ejector

An in-built tip ejector is designed to eject tips with optimal force.

Use Various Tips with Universal Tipcone

Use Various Tips with Universal Tipcone

Our tip-cone is designed to be compatible with most internationally accepted tips, which enhances the compatibility of the instrument in the industry.

Adjust volume with perfection

Adjust volume with perfection

A distinct click at every volume change ensures perfect volume setting and prevents any accidental volume change.

Color Coding for Easy Identification

Color Coding for Easy Identification

Color-coding for different volume ranges enables easy identification during daily laboratory routine.

Model No. Description Vol. Range(uL) Increment(uL) Accuracy CV
+% +uL +% +uL
NRO-2 Micropipette NRO Series Vol. Range 0.2-2µL 0.2-2.0ul 0.01 2 0.04 1.2 0.024
NRO-10 Micropipette NRO Series Vol. Range 0.5-10µL 0.5-10ul 0.05 1 0.1 0.5 0.05
NRO-20 Micropipette NRO Series Vol. Range 2-20µL 2-20ul 0.1 0.8 0.16 0.4 0.08
NRO-50 Micropipette NRO Series Vol. Range 5-50µL 5-50ul 0.2 0.8 0.4 0.4 0.2
NRO-100 Micropipette NRO Series Vol. Range 10-100µL 10-100ul 0.5 0.6 0.6 0.2 0.2
NRO-200 Micropipette NRO Series Vol. Range 20-200µL 20-200ul 1.0 0.6 1.2 0.2 0.4
NRO-1000 Micropipette NRO Series Vol. Range 100-1000µL 100-1000ul 5.0 0.6 6 0.2 2
NRO-5000 Micropipette NRO Series Vol. Range 500-5000µL 0.5-5ml 20.0 0.6 30 0.2 10
NRO-10000 Micropipette NRO Series Vol. Range 1-10ml 1-10ml 50.0 0.6 60 0.2 20

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance with DIN EN ISO 8655-2 and are based on the nominal capacity indicated on the instrument. MICROLIT NERO is calibrated in an ISO 17025 accredited laboratory according to ISO 8655 standards and a Calibration Certificate is included in the product package.

What our Customers are saying

NERO Pipette Set

NERO 3-Micropipette Starter Kit

  • 3 Microlit Lab Adjustable Micropipettes (2-20ul, 20-200ul, 100-1000ul)
  • Compatible tip boxes/packets included
  • Universal Tipcone – compatible with most internationally accepted tips
  • Achieve high precision with uAir™ technology
  • Calibrate efficiently in one shot with UniCal™ technology 
  • Lightweight with a soft grip for utmost user comfort
  • Different Color Coding on top for Easy Identification
  • Fully autoclavable at 121° C, 15psi. for at least 15 mins
  • Calibration certificate provided – Conforms to ISO 8655 standards
See More See Less

Microlit NERO Micropipette Starter Kit combines 3 single channel pipettes to cover the complete pipetting range (2-20ul pipette, 20-200ul pipette, 100-1000ul pipette). The NERO micropipette kit also includes a beautiful carousel stand and boxes of compatible tips for each pipette so that you do not have to go looking for the right tips.

Each of the four Microlit NERO Single Channel Variable Volume Micropipettes are high precision adjustable micropipettes with state-of-the-art technology such as UniCal™ and Air™ that will ensure great precision and convenience for our lab users. These innovative and patented technologies have been developed by our in-house product design engineers. The product is highly recommended for pathology, microbiology, and diagnostic testing labs where precise small volume pipetting is critical.

What’s in the box?

  1. 3 Microlit Adjustable Volume Pipettes (2-20ul, 20-200ul, 100-1000ul)
  2. 1 carousel pipette stand
  3. R-200-NS-W (upto 200ul) pipette tips (box of 96)
  4. R-1000-NS-W (1000ul) pipette tips (box of 96)
  5. Calibration Tools
  6. Micropipette holders
  7. Calibration Certificates
  8. Instruction Manuals
Features
Achieve precision with uAir™ technology

Achieve precision with uAir™ technology

The design of Microlit NERO ensures minimum dead air space between the piston and the liquid in the tip. This reduces air compression and enables the user to achieve precision in practical lab conditions.

Calibrate Efficiently with UniCal™ Technology

Calibrate Efficiently with UniCal™ Technology

We have introduced a unique calibration mechanism/tool which allows quick in-lab calibration in a single operation WITHOUT disengaging the digits from the plunger mechanism.

Eject Tips Easily with our Tip Ejector

Eject Tips Easily with our Tip Ejector

An in-built tip ejector is designed to eject tips with optimal force.

Use Various Tips with Universal Tipcone

Use Various Tips with Universal Tipcone

Our tip-cone is designed to be compatible with most internationally accepted tips, which enhances the compatibility of the instrument in the industry.

Adjust volume with perfection

Adjust volume with perfection

A distinct click at every volume change ensures perfect volume setting and prevents any accidental volume change.

Color Coding for Easy Identification

Color Coding for Easy Identification

Color-coding for different volume ranges enables easy identification during daily laboratory routine.

Model No. Description Vol. Range(uL) Increment(uL) Accuracy CV
+% +uL +% +uL
NRO-2 Micropipette NRO Series Vol. Range 0.2-2µL 0.2-2.0ul 0.01 2 0.04 1.2 0.024
NRO-10 Micropipette NRO Series Vol. Range 0.5-10µL 0.5-10ul 0.05 1 0.1 0.5 0.05
NRO-20 Micropipette NRO Series Vol. Range 2-20µL 2-20ul 0.1 0.8 0.16 0.4 0.08
NRO-50 Micropipette NRO Series Vol. Range 5-50µL 5-50ul 0.2 0.8 0.4 0.4 0.2
NRO-100 Micropipette NRO Series Vol. Range 10-100µL 10-100ul 0.5 0.6 0.6 0.2 0.2
NRO-200 Micropipette NRO Series Vol. Range 20-200µL 20-200ul 1.0 0.6 1.2 0.2 0.4
NRO-1000 Micropipette NRO Series Vol. Range 100-1000µL 100-1000ul 5.0 0.6 6 0.2 2
NRO-5000 Micropipette NRO Series Vol. Range 500-5000µL 0.5-5ml 20.0 0.6 30 0.2 10
NRO-10000 Micropipette NRO Series Vol. Range 1-10ml 1-10ml 50.0 0.6 60 0.2 20

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance with DIN EN ISO 8655-2 and are based on the nominal capacity indicated on the instrument. MICROLIT NERO is calibrated in an ISO 17025 accredited laboratory according to ISO 8655 standards and a Calibration Certificate is included in the product package.

What our Customers are saying

Pipette Sets and Starter Kit

NERO Pipette Set

  • 3 Microlit Lab Adjustable Micropipettes (2-20ul, 20-200ul, 100-1000ul)
  • Universal Tipcone – compatible with most internationally accepted tips
  • Achieve high precision with uAir™ technology
  • Calibrate efficiently in one shot with UniCal™ technology 
  • Lightweight with soft grip for utmost user comfort
  • Different Color Coding on top for Easy Identification
  • Fully autoclavable at 121° C, 15psi. for at least 15 mins
  • Calibration certificate provided – Conforms to ISO 8655 standards
See More See Less

Microlit NERO Micropipette Set combines the most frequently used single channel pipettes (2-20ul pipette, 20-200ul pipette, 100-1000ul pipette) into a compact package. Each of the three Microlit NERO Single Channel Variable Volume Micropipettes are high precision adjustable micropipettes with state-of-the-art technology such as UniCal™ and Air™ that will ensure great precision and convenience for our lab users. These innovative and patented technologies have been developed by our in-house product design engineers. The product is highly recommended for pathology, microbiology, and diagnostic testing labs where precise small volume pipetting is critical.

 

What’s in the box?

  1. 3 Microlit Adjustable Volume Pipettes (2-20ul, 20-200ul, 100-1000ul)
  2. 1-2 compatible micropipette tips
  3. Calibration Tool
  4. Micropipette holder
  5. Calibration certificate
  6. Instruction manual
Features
Achieve precision with uAir™ technology

Achieve precision with uAir™ technology

The design of Microlit NERO ensures minimum dead air space between the piston and the liquid in the tip. This reduces air compression and enables the user to achieve precision in practical lab conditions.

Calibrate Efficiently with UniCal™ Technology

Calibrate Efficiently with UniCal™ Technology

We have introduced a unique calibration mechanism/tool which allows quick in-lab calibration in a single operation WITHOUT disengaging the digits from the plunger mechanism.

Eject Tips Easily with our Tip Ejector

Eject Tips Easily with our Tip Ejector

An in-built tip ejector is designed to eject tips with optimal force.

Use Various Tips with Universal Tipcone

Use Various Tips with Universal Tipcone

Our tip-cone is designed to be compatible with most internationally accepted tips, which enhances the compatibility of the instrument in the industry.

Adjust volume with perfection

Adjust volume with perfection

A distinct click at every volume change ensures perfect volume setting and prevents any accidental volume change.

Color Coding for Easy Identification

Color Coding for Easy Identification

Color-coding for different volume ranges enables easy identification during daily laboratory routine.

Model No. Description Vol. Range(uL) Increment(uL) Accuracy CV
+% +uL +% +uL
NRO-2 Micropipette NRO Series Vol. Range 0.2-2µL 0.2-2.0ul 0.01 2 0.04 1.2 0.024
NRO-10 Micropipette NRO Series Vol. Range 0.5-10µL 0.5-10ul 0.05 1 0.1 0.5 0.05
NRO-20 Micropipette NRO Series Vol. Range 2-20µL 2-20ul 0.1 0.8 0.16 0.4 0.08
NRO-50 Micropipette NRO Series Vol. Range 5-50µL 5-50ul 0.2 0.8 0.4 0.4 0.2
NRO-100 Micropipette NRO Series Vol. Range 10-100µL 10-100ul 0.5 0.6 0.6 0.2 0.2
NRO-200 Micropipette NRO Series Vol. Range 20-200µL 20-200ul 1.0 0.6 1.2 0.2 0.4
NRO-1000 Micropipette NRO Series Vol. Range 100-1000µL 100-1000ul 5.0 0.6 6 0.2 2
NRO-5000 Micropipette NRO Series Vol. Range 500-5000µL 0.5-5ml 20.0 0.6 30 0.2 10
NRO-10000 Micropipette NRO Series Vol. Range 1-10ml 1-10ml 50.0 0.6 60 0.2 20

 

The error limits (Accuracy and Coefficient of Variation) mentioned above are in accordance with DIN EN ISO 8655-2 and are based on the nominal capacity indicated on the instrument. MICROLIT NERO is calibrated in an ISO 17025 accredited laboratory according to ISO 8655 standards and a Calibration Certificate is included in the product package.

What our Customers are saying

Microlit NRO micropipettes have a universal tip and are compatible with standard universal-fit tips. However, we recommend using Microlit ProTips for the best results.
The micropipette is fully autoclavable at 121'C for at least 15 mins at 15 psi.
All micropipettes are calibrated as per the ISO 8655 norms, which confirms the accuracy and precision of the liquid handling instruments. However, it is suggested to re-calibrate or get your micropipette once in 6 months if it is used regularly.
Set the micropipette at the nominal volume and dispense distilled water at least five times. Measure the dispensed liquid on an analytical or electronic balance. If the mean and CV of the readings is within the acceptable ISO limits (see specs chart), the pipette is calibrated. If not, please follow the recalibration procedure in the instruction manual.
Yes, the micropipette is supplied with a few sample tips only. However, Microlit ProTips are available in racked, reloads, and bulk packaging for additional purchases.
As per ISO 8655, it is recommended to get your micropipette checked annually. However, based on the usage the micropipettes can be re-checked every 3 or 6 months.
It is a good practice to pre-rinse the tip, especially while working with liquids with high vapor pressure, and every time the tip is changed or the volume of the pipette is changed. Pre-rinsing reduces the capillary effect in low-volume pipettes and it neutralizes the temperature of the tip with the sample in high-volume pipette tips. Thereby, increasing the chances of the accuracy of an experiment.
The best technique for pipetting any viscous/foaming liquid is the Reverse Pipetting technique. To start with, set the desired volume and depress the plunger till the SECOND step. Immerse the tip inside the liquid and slowly release the plunger. Depress the plunger till the FIRST step only to get the desired volume. The residual (blow-out) volume is discarded. For different pipetting techniques, please refer to the instruction manual.
Use of low retention tips is suggested while working with detergents, foaming liquids as well as viscous solutions. Due to its hydrophobicity and low adhesion property, the surface contact between the tip and liquid is less. Thereby, reducing the loss of valuable reagents. Please find Microlit ProTip™ low retention tips in the Tips section.
The design of 5ml and 10ml tip cones is different for each manufacturer and so universal-fit tips will not work. To ensure compatibility, please refer to Microlit ProTip™ low retention tips in the Tips section.